Reply 220 of 222, by polpo
- Rank
- Member
bjwil1991 wrote on 2021-08-01, 22:40:I was doing some reflowing on the GUS Max 2.1 card since it would lock up at the detection using the DOS setup program or when I enable it in Windows 95C's device manager. I reflowed the following to see if the issue would get fixed:
[...]
Apparently, the ICS1614 GF1 chip is done for and the card isn't detected any longer (throws an error saying the HW address is in use, the CD drive isn't detected, and so on).
The GF1 is almost certainly fried. I had the same symptoms on my original GUS board and replacing the GF1 fixed it. Here's a thread I made about the issue: Bringing a Gravis Ultrasound back from the dead