VOGONS


RS232 COM Port

Topic actions

First post, by brian_fenner

User metadata
Rank Newbie
Rank
Newbie

Hello!

New to DOSBOX but have it up and running on WIN7x64 system to run some old DOS programs communicating to a data logger.
Program comes up and seems to run just fine in DOSBOX..........but I'm unable to communicate to device connected to COM port (RS232). I have verified that all settings are correct.

Any ideas?
Should this work running in the DOSBOX environment?

Thanks for any help....

Reply 1 of 2, by h-a-l-9000

User metadata
Rank DOSBox Author
Rank
DOSBox Author

[serial] in the config file

1+1=10

Reply 2 of 2, by brian_fenner

User metadata
Rank Newbie
Rank
Newbie

Thanks............

Yes I just found that and moified it like the following:

“serial1=directserial realport:com1”

Worked like a champ!
Didn't realize the ports were defaulted to "dummy"

Thanks for the feedback!
I'm a happy camper. 😁