Reply 1600 of 2175, by Falcosoft
- Rank
- l33t
Roland User wrote on 2024-01-08, 10:59:I firs thinked what if sent GM OFF on OPL or XG device , will be work with errors or not play default patches. But to having hea […]
I firs thinked what if sent GM OFF on OPL or XG device , will be work with errors or not play default patches.
But to having heard from you what alll be good , I do modify reset file and add to this GM OFF message ) now reset file looks like thatF0 41 10 16 12 7F 01 F7
F0 7E 7F 09 01 F7
F0 43 10 4C 00 00 7E 00 F7
F0 41 10 42 12 40 00 7F 00 41 F7and will be so :
F0 41 10 16 12 7F 01 F7
F0 7E 7F 09 01 F7
F0 43 10 4C 00 00 7E 00 F7
F0 41 10 42 12 40 00 7F 00 41 F7
F0 7E 7F 09 02 F7but now problem , if I sent this in Cakewalk and create MID file , I can not do serial reset , as need modify MID file so serial reset ?
I do not understand your question.
All I can say is that in case of GS devices that know this message GM OFF means default GS mode and in case of XG devices GM OFF means default XG mode (That is why I chose it for Munt VSTi . The logic is the same: Gm OFF means default MT-32 mode but with potentially 16-channels). OPL synths usually simply ignore GM OFF just like they also ignore GM ON.
BTW, GM OFF is F0 7E 7F 09 02 F7 (not F0 7E 7F 09 01 F7 , that is GM ON).