Reply 28900 of 29597, by DaveDDS
- Rank
- Oldbie
Tiido wrote on 2024-12-11, 16:26:That is not nixies but VFDs. One has lost its vacuum unfortunately. If nothing lights up you'll have to see that filament supply is in order and that its bias circuit with system ground is still good (usually a zener is used for that). Anode voltage must also be present of course, 20...50V, depending on particular tubes used and whatever the multiplexing rate is.
Apologies, I guess I didn't look that close (segments should have given in away) - I built a lot of stuff with nixies back in the day
(don't want to even think how long since I've even seen one live) - and I guess I still tend to think of tube displays as nixies. (kinds
miss these full digit elements)
Agreed, if no segments are showing at all, I'd suspect one of the supplies first!
Dave ::: https://dunfield.themindfactory.com ::: "Daves Old Computers"->Personal
Dave ::: https://dunfield.themindfactory.com ::: "Daves Old Computers"->Personal