Could someone maybe do me a favor and test their ARGUS with a 16 MB SIMM in Interwave mode against Cubic Player 2.00a (https://archive.org/details/cp2appe_zip)?
With the 16MB SIMMs I have on my card (single or double sided, but all with 8 ICs), which is not an ARGUS though, the samples do sound totally broken in Interwave mode, while it does work in (the memory limited) Ultrasound mode. Trying Impulse Tracker, Interwave mode seems to work fine (though I didn't have any module to fill 8MB or more). At first I was suspecting Cubic Player, but swapping the modules for 8MB ones, it started working nicely in both players. Sadly, the official PNP only came with two 30pin banks, otherwise I would have tested it on there.
I'm still trying to understand the organisation of the SIMM modules, since so far, with seeing there are MA0 to MA10 available on the Interwave and A11 not connected on the SIMM socket, I'm arriving at 2^11=2048 addresses with 4 banks used (BKSEL[0-3]), which would make an 8MB limit seem plausible to me (as is also mentioned for the official PNP). Where am I going wrong there? Also, checking the 16 MB module on the card, with the included setup program, they do test fine - so, my amateur theory right now is, it's just testing 8MB of it twice?