First post, by 640KB
- Rank
- Newbie
I have a Sony MP-F40W-18, ED/2.88 MB floppy drive that is almost working. I followed the mods that were outlined in this post, and the drive spins and even reads data. However, the drive does not correctly seek/step - it only steps one direction (out) and of course hits the end track fairly quickly. Using Image Disk, I was also able to read sectors on the track where the head is sitting, so it otherwise functions.
If I probe pin 18 on a normal, working drive I see the correct DIR while seeking:
However, when this drive is plugged in, the DIR line never goes low and my scope does not trigger - something is pulling it high and keeping it high. This of course makes sense as the cause for why it's doing what it's doing.
I was able to find this schematic (page 53) for a similar model that seems to mostly line up with what I've traced out. I can confirm that the 1K pull-ups all measure 1K, and the diodes in the network measure 1.1v drop one way and 0.5v drop the other way... since they're all kind of in parallel I'm not entirely sure if that's okay or not. I have not yet pulled the board entirely out, just out of caution due to all of the little brittle ribbon cables I'd have to disconnect but may have to do so to ensure that the trace to the control chip isn't somehow open.
Attaching a photo of the bottom for comparison to the ones in the previous post.
Would love any thoughts or suggestions for what to look at next. I really don't want to give up on this drive!
640KB